For 5 minutes, at least one path for a DM-multipath device has been outside
the active state at each evaluation. The failed paths can change between
evaluations. The metrics come from the node-exporter dmmultipath collector.
When that collector is unavailable or disabled, or no multipath devices
exist, this alert does not fire.
Path redundancy is degraded. I/O can continue through usable paths, but further failures may disrupt access to the device. If all paths are already failed, applications and VMs using the device may have blocked I/O.
MultipathPathCritical can fire alongside this alert.
Use the alert’s instance, device, and sysfs_name labels to identify the
node and DM-multipath device. The instance label identifies the node-exporter
scrape target; confirm the corresponding node before inspecting it.
On the affected node, inspect the device and its underlying paths:
multipath -ll <device>
dmsetup info <device>
dmsetup status <device>
journalctl -u multipathd
Check storage fabric connectivity, HBA and switch ports, array controllers, and iSCSI sessions where applicable. Correlate with storage maintenance and recent configuration changes.
In Prometheus, compare the failed and total path metrics for the same instance, device, and sysfs name. Run each query separately:
node_dmmultipath_device_paths_failed{job="node-exporter",instance="<instance>",device="<device>",sysfs_name="<sysfs_name>"}
node_dmmultipath_device_paths{job="node-exporter",instance="<instance>",device="<device>",sysfs_name="<sysfs_name>"}
If the paths recover before you run these queries, the instant results show zero failed paths and do not establish the earlier condition. To inspect the incident window, graph both selectors in the Prometheus console over the alert’s firing period and compare failed and total paths over time.
The path metrics classify SCSI running and NVMe live as active. They report
underlying device state, not multipathd path-checker or ALUA state. Missing
metrics do not establish that storage is healthy.
Restore the failed storage paths with the storage administrator. Check cable
and transceiver health, zoning, HBA ports, storage sessions, and array ports.
Before closing the incident, recheck multipath -ll on the affected node and
confirm that affected workload I/O is healthy: the failed-path count and the
alert can clear while multipath still marks a path unusable. Do not remove
the mapped device while workloads are using it.
If you cannot resolve the issue, see the following resources: